Slab pre-pour inspection in Wyndham Vale

Beams, pods, mesh and underlay all checked in the hours before the concrete truck. After that, whatever is wrong is cast in for the life of the house.

  • The day before the pour, when pods, mesh and underlay are all still open
  • About 1 hour on site
  • Report within 24 hours
Request your quoteChoose the inspection and we will come back to you with a price.

No obligation. We use your details for your quote and may contact you about it even if you don't finish.

Fully licensed & accredited

Stage2 of 7
When to bookThe day before the pour, when pods, mesh and underlay are all still open
Time on siteAbout 1 hour on site
Inspected againstAS 2870, AS 3600, NCC Part 3.2, the engineer's slab design and the soil report

What is included in a Wyndham Vale slab pre-pour inspection

  • Slab class and layout checked against the engineer's design and the soil report
  • Edge beam and internal beam depths and widths
  • Reinforcement size, spacing, laps and trench mesh
  • Bar chairs, cover and support so steel does not sit on the ground
  • Waffle pods, void formers and pod spacing
  • Vapour barrier coverage, laps and tape at penetrations
  • Plumbing and electrical penetrations and sleeves
  • Set-downs for wet areas, garage, porch and alfresco
  • Termite management components installed before the pour
  • Formwork alignment, level and set-out against the plans
  • Stormwater pipe cover and pit positions where visible
  • Site cut, fill and pier holes where visible
  • Hot water service and meter box slab extensions formed
  • Trench cleanliness and debris before the pour
Why it matters here

Slab pre-pour inspections on Wyndham Vale builds

On the reactive clay of the volcanic plain the slab is designed with stiffening beams for a reason. A beam poured narrow, or underlay that stops short, weakens exactly what that ground needs.

What we find at this stage in Wyndham Vale

  • Internal beam narrower than the engineering width
  • Waffle pods shifted out of their drawn positions
  • Underlay not continuous under the slab and beams
  • Penetrations through the underlay left untaped
  • Mesh sagging without enough support
  • Termite collars missing at plumbing penetrations
Waffle pods not laid out to the positions on the engineering, found during a slab pre-pour inspection in Hoppers Crossing
Waffle pods not laid out to the positions on the engineering, Hoppers Crossing
Strip drain to the garage edge beam not yet completed, found during a slab pre-pour inspection in Hoppers Crossing
Strip drain to the garage edge beam not yet completed, Hoppers Crossing
Formwork boards out of line and needing extra bracing, found during a slab pre-pour inspection in Altona North
Formwork boards out of line and needing extra bracing, Altona North
Slab underlay without the continuous printed marking the standard requires, found during a slab pre-pour inspection in Altona North
Slab underlay without the continuous printed marking the standard requires, Altona North
Sample findings

Sample defects found during our slab pre-pour inspections in Wyndham Vale

Annotated findings from Slab pre-pour inspections.

Internal slab beam only 50mm wide where the engineering called for 110mm, found during a slab pre-pour inspection in Hoppers Crossing
Internal slab beam only 50mm wide where the engineering called for 110mm, Hoppers Crossing
Vapour barrier stopping short of the full slab and beam area, found during a slab pre-pour inspection in Hoppers Crossing
Vapour barrier stopping short of the full slab and beam area, Hoppers Crossing
Termite collars missing from plumbing penetrations through the slab, found during a slab pre-pour inspection in Altona North
Termite collars missing from plumbing penetrations through the slab, Altona North
Slab mesh sagging where it has not been properly supported, found during a slab pre-pour inspection in Hoppers Crossing
Slab mesh sagging where it has not been properly supported, Hoppers Crossing

The other stages of a Wyndham Vale build

  1. Bored piers inspection in Wyndham Vale1Bored piersWith piers bored and cages in, before the concrete is ordered
  2. Frame inspection in Wyndham Vale3FrameFrame and trusses complete and roof on, before wall wrap and insulation
  3. Lock-up (pre-plaster) inspection in Wyndham Vale4Lock-up (pre-plaster)Roof, windows and external doors in, before the plasterer starts
  4. Fixing inspection in Wyndham Vale5FixingDoors, skirtings and cabinets in, before the painter arrives
  5. Waterproofing inspection in Wyndham Vale6WaterproofingMembrane applied and cured, before the tiler sets out
  6. Pre-handover (PCI) inspection in Wyndham Vale7Pre-handover (PCI)Five to seven days before the practical completion date

All construction stage inspections in Wyndham Vale →

Guides

Construction stage guides for Wyndham Vale

All guides →

Book a slab pre-pour inspection in Wyndham Vale

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Slab pre-pour inspections in Wyndham Vale: common questions

How late can I book a slab inspection?

A day ahead normally works, but tell us the pour date as soon as the builder gives it.

What happens when you find a problem?

The report goes to you that afternoon so you can pass it to the supervisor, and most items are fixed before the truck arrives.

Why does beam width matter so much?

Stiffening beams are what let a slab ride out clay movement. A beam half its designed width does not do that job.

Will the inspection hold up my pour?

The pour date is a matter for you and your builder to settle. Most slab items take a few hours to correct.

What standard is the slab checked against?

AS 2870 together with the engineering drawing for your lot.

Can the slab be checked after the pour?

Only the edges and surface. Everything inside it is out of sight for good.